Re: XForms: Problems with xyplot postscript dump

Dr. T.C. Zhao (zhao@bragg.phys.uwm.edu)
Thu, 16 Oct 1997 22:18:29 -0500

To subscribers of the xforms list from "Dr. T.C. Zhao" <zhao@bragg.phys.uwm.edu> :

from Ivan Powis <pczip@chemistry.nottingham.ac.uk> :

>(1) if the xyplot label is positioned outside the plotting box, say
> fl_set_object_lalign(obj,FL_ALIGN_BOTTOM_RIGHT);
confirmed and fixed. flps_draw_text failed to take care
of mixed alignment.

>(2) if I have used
> fl_set_xyplot_alphaytics(fd_fff->xyplot,"","");

confirmed and fixed.

>(3) If I have enabled double buffering of the plot
> fl_set_object_dblbuffer(fd_fff->xyplot,TRUE);

confirmed and fixed.

I was kind of worried about lack of bug reports on fl_object_ps_dump().
It's not possible to get everything right the first time. Now,
aftering fixing some minor color problems and all of the
above, I am no longer worried :-)

Thanks for the detailed report and info about reproducing the
problem.

>of non-zero for ON or whether it is a specific test for 1=ON anything else
>OFF. Really why I ask this is that I notice that after flps_init()
>eps=0 auto_fit=1 drawbox=-1 (the latter is apparently OFF, and requires
>drawbox=1 to function)

All binary options should be set to 1 for true. -1 was used internally
to indicate "auto".